Blower Motor Keeps Running: Causes, Solutions, and Maintenance Tips

If your blower motor keeps running continuously, it could be due to a thermostat set to “ON” instead of “AUTO,” a stuck relay switch, or a malfunctioning fan limit switch. Other potential causes include wiring issues or overheating of the furnace. Checking the thermostat settings and inspecting the electrical components can help diagnose the problem, but consulting an HVAC professional may be necessary for a proper fix.

When your blower motor keeps running continuously, it can be both a frustrating and confusing issue. This component, essential for circulating air through your HVAC (Heating, Ventilation, and Air Conditioning) system, is designed to turn on and off in cycles, depending on your thermostat settings. However, if it runs nonstop, it can lead to increased energy bills, unnecessary wear and tear on your system, and uncomfortable indoor conditions.

In this detailed blog post, we’ll explore the potential causes of a continuously running blower motor, how to diagnose the issue, solutions to fix it, and preventive measures to keep your system in good working order.

Causes of Blower Motor Keeps Running

If your blower motor keeps running, several potential issues could be the cause. Below are the most common reasons, along with explanations for each.

1. Thermostat Settings

  • Fan Setting: One of the most straightforward explanations is that your thermostat is set to “ON” instead of “AUTO.” When the fan is set to “ON,” the blower motor runs continuously, regardless of whether the system is heating or cooling. In contrast, the “AUTO” setting allows the blower to run only during active heating or cooling cycles.
  • Solution: Check your thermostat and ensure the fan setting is on “AUTO.” This simple adjustment might solve the issue immediately.

2. Thermostat Malfunction

  • Faulty Thermostat: If your thermostat is malfunctioning, it may send incorrect signals to the blower motor, causing it to run continuously. This could be due to an internal fault in the thermostat or wiring issues that prevent the system from receiving the correct instructions.
  • Solution: Test the thermostat by adjusting the temperature settings and observing the blower motor’s response. If the motor continues to run even when the thermostat is off, the thermostat may need to be repaired or replaced. Consider consulting a professional HVAC technician to diagnose and fix the issue.

3. Relay Switch Issues

  • Stuck Relay: The blower motor relies on a relay switch to receive the electrical signal to turn on and off. If the relay switch gets stuck in the “on” position, the blower motor will continue to run even when it’s not needed. Relay switches can become stuck due to wear and tear, electrical problems, or debris.
  • Solution: If you’re familiar with electrical components, you can test the relay switch to see if it’s functioning correctly. If it’s stuck, the switch may need to be cleaned or replaced. For those unfamiliar with HVAC electrical systems, it’s advisable to contact a professional for this task.

4. Fan Limit Switch Malfunction

  • Fan Limit Switch: The fan limit switch is a safety device found in your furnace that controls when the blower motor turns on and off. It ensures that the blower motor only operates when the furnace is at the correct temperature. If this switch malfunctions, it might cause the blower to run continuously to prevent overheating.
  • Solution: Diagnosing a faulty fan limit switch usually requires the help of an HVAC technician. They will inspect the switch to determine if it needs recalibration or switch replacement.

5. Stuck Contactor

  • Contactor Issues: The contactor is another electrical component that controls the blower motor’s operation. If the contactor becomes stuck in the closed position, it will keep the motor running. This issue is more common in older HVAC systems where components are more prone to wear and tear.
  • Solution: Inspect the contactor for signs of damage or corrosion. If the contactor is stuck or damaged, it will need to be replaced. Again, this is a job best handled by an HVAC professional.

6. Wiring Problems

  • Faulty Wiring: Loose, damaged, or faulty wiring can cause the blower motor to receive constant power, leading to continuous operation. Wiring problems can arise from poor installation, age-related wear, or damage from pests.
  • Solution: Inspect the wiring around your blower motor and thermostat for visible signs of damage. If you notice any frayed wires, loose connections, or scorch marks, turn off the power to the system and call an HVAC technician to address the issue safely.

7. Dirty Air Filter

  • Clogged Air Filter: A clogged or dirty air filter can restrict airflow, causing the blower motor to work harder and potentially run continuously in an attempt to maintain airflow. While this issue is less likely to cause the motor to run nonstop, it can contribute to overall system inefficiency.
  • Solution: Regularly check and replace your air filter according to the manufacturer’s recommendations-usually every 1-3 months. A clean air filter not only prevents the blower motor from overworking but also improves overall system efficiency.

8. Furnace Overheating

  • Overheating Issues: If your furnace is overheating, the blower motor may run continuously to cool the system down. Overheating can be caused by various issues, such as dirty burners, restricted airflow, or a failing heat exchanger.
  • Solution: If you suspect overheating, it’s important to address the root cause immediately to prevent further damage. Turn off the furnace and call a professional to inspect and repair the system.

Diagnosing the Problem

When faced with a continuously running blower motor, diagnosing the problem involves a systematic approach to identify the root cause.

  1. Check Thermostat Settings: Start by verifying that the thermostat is set to “AUTO” and not “ON.” If the setting is correct, move on to other potential issues.
  2. Inspect the Thermostat: Adjust the thermostat temperature and observe if the blower motor responds appropriately. If not, consider testing the thermostat or replacing it.
  3. Test the Relay Switch: If you’re comfortable with electrical work, test the relay switch to see if it’s stuck in the “on” position. If you’re unsure, contact a professional.
  4. Examine the Fan Limit Switch: If the blower motor continues running despite the furnace being off, the fan limit switch may be the culprit. This requires professional inspection.
  5. Check the Contactor and Wiring: Inspect the contactor and wiring for any signs of wear, corrosion, or damage. Replace or repair faulty components as necessary.
  6. Inspect the Air Filter: Ensure the air filter is clean and free from obstructions that could cause the blower motor to overwork.
  7. Consider Overheating Issues: If you notice that the blower motor runs excessively after the furnace has been on, overheating might be the issue. Turn off the system and call a professional.

How to Prevent Blower Motor Keeps Running

Preventing your blower motor from running continuously involves regular maintenance and addressing minor issues before they escalate.

1. Regular HVAC Maintenance

  • Annual Inspections: Schedule annual inspections with a professional HVAC technician to ensure all components, including the blower motor, are in good working order.
  • Seasonal Maintenance: Before the start of each heating or cooling season, perform basic maintenance such as cleaning air filters, checking thermostat settings, and inspecting wiring.

2. Monitor Thermostat Settings

  • Use Programmable Thermostats: Programmable thermostats allow you to set specific temperatures for different times of the day, reducing the risk of the blower motor running unnecessarily.
  • Regularly Check Settings: Periodically check your thermostat settings to ensure they are set correctly and that the system is functioning as expected.

3. Replace Air Filters

  • Routine Replacement: Replace air filters every 1-3 months or as recommended by the manufacturer. This helps maintain proper airflow and reduces strain on the blower motor.
  • Use High-Quality Filters: Invest in high-quality air filters that effectively trap dust and debris, protecting your blower motor and other HVAC components.

4. Address Electrical Issues Promptly

  • Fix Wiring Problems: If you notice any issues with your HVAC system’s wiring, such as flickering lights or tripped breakers, address them promptly to prevent damage to the blower motor.
  • Protect Against Surges: Use surge protectors to protect your HVAC system from power surges that could damage the blower motor and other components.

Conclusion

A blower motor that keeps running can be a sign of various issues, ranging from simple thermostat settings to more complex electrical or mechanical problems. By understanding the potential causes and following a systematic approach to diagnose and address the issue, you can prevent unnecessary wear and tear on your HVAC system and maintain a comfortable home environment.